[ Accessories ]

Complete the Measurement Picture.

Four precision accessories. From clamp-on data pickup to irradiance and temperature reference — completing the measurement picture without separate data wiring.

SunSniffer · Accessoriesmeasuring
MC4PYRANOMETERirradiance · W/m²PT100 KIT5-point temperature mapDSPDSP BOARDsignal filter · 2×2 cm
no separate data wiringPLC over DC cables
Accessory · 01
[ PYRANOMETER ]

Precision Irradiance Measurement at String Level.

Measures global irradiance (W/m²) directly at string level. The pyranometer connects via RS485 directly to the Gateway — or to the DC line via MC4 connectors, transmitting to the String Reader through our patented PLC communication over the existing DC cables. Irradiance measured at the string, not at a distant weather station, gives the most accurate local reference. Essential for TrueSTC calculations, Performance Ratio validation, and precise correlation between conditions and module performance.

Measurement
Global irradiance W/m²
Connection
RS485 to Gateway — or MC4 to DC line
Communication
Patented PLC to String Reader
Data cable
Not required — PLC over DC cables
PYRANOMETER · IRRADIANCEW/m² · live
RS485GATEWAYMC4 → DCPLCSTRING READERor
RS485 → Gateway · or · MC4 → DC linepatented PLC
Accessory · 02
[ PT100 TEMPERATURE KIT ]

Five-Point Temperature Mapping Across a Single Module.

Five Class A PT100 temperature sensors bonded to five measurement points across the backsheet of one reference module. Temperature is not uniform — cell temperature can vary significantly between center and edges, between shaded and unshaded areas. Five measurement points reveal the full thermal profile. The five sensors communicate via RS485, with a connector to Modbus — or from there onto the DC line via MC4 connectors, transmitting through our patented PLC communication over the existing DC cables. Critical for accurate TrueSTC calibration and for detecting thermal anomalies single-point sensors would miss entirely.

Sensors per kit
5 × Class A PT100
Measurement points
Five positions across the backsheet
Sensor bus
RS485
Output
Modbus connector — or PLC via MC4 to DC line
Communication
Patented PLC over the DC cables
Use case
TrueSTC calibration, anomaly detection
PT100 KIT · 5-POINT MAPPLC · transmitting
T1T2T3T4T5RS485MODBUSMC4 → DC · PLCor
5 × PT100 → RS485Modbus · or · PLC via MC4
Accessory · 03
[ DSP — SIGNAL CLARITY ]

Clean PLC Signals. Even in Central Inverter Plants.

A Digital Signal Processor board that plugs into the dedicated slot built into every String Reader. Filters inverter switching noise from PLC signals — essential in plants with large central inverters where electrical interference can reduce PLC communication reliability. Not required for standard string inverter installations. Every String Reader ships with the DSP slot ready — the board is an optional addition ordered separately.

⚠ WARNINGInstallation must be carried out by authorized and trained SunSniffer personnel only. Incorrect installation can damage the String Reader unit.
Form factor
PCB — plugs into built-in slot
Required for
Central inverter environments
Installation
SunSniffer-authorized personnel only
Included standard
No — optional addition
DSP BOARD · SIGNAL FILTERfiltering
DSP20 mm20 mmsimulated render · actual size 2 × 2 cm
plugs into String Reader slotfilters inverter noise
Accessory · 04
[ STRING CLAW ]

Clamp-On PLC Pickup. No Cable Opened.

A clamp-on data pickup for PV string cables. The String Claw clips around the string cable next to the inverter and reads the module-level data transmitted over the PV cable — module voltage and module temperature — without opening or disconnecting anything. It plugs straight into a USB port of the X-String Reader: clamp, plug, done. String current is not measured by the claw; current data is taken from the inverter and combined with the module data in the Gateway.

Function
Picks up PLC module data from the string
Signal detection
100 kHz – 500 kHz
Cable diameter
10–12 mm (6 & 10 mm² PV cable)
DC current on cable
0–20 A
Interface
USB 2.0 → X-String Reader
Cable length
1.5 / 3 / 5 m (option)
String current
From inverter — merged in Gateway
String Claw — clamp-on PLC pickup with USB interface
String Claw · clamp-on PLC pickupwith X-String Reader →

Build Your Measurement Kit.

Every accessory connects via PLC. No extra wiring. No separate data network.

Download Datasheet Contact Engineering